|
![]() |
| OmniDrive USB Professional V1.73 | (C) 2003 CSM GmbH Filderstadt |
Drivers & Tools for the OmniDrive USB Professional for the operating systems:
- Windows 2000
- Windows XP
- Windows 98/Me
COPYRIGHT
LIMITED WARRANTY
TRADEMARKS
SAFETY INFORMATION
1.) Introduction
2.) Installation
2.1.) Hardware Requirements
2.2.) Hardware-Installation
2.3.) Software Installation
3.) Operating Instructions
3.1.) Formatting
3.2.) Selecting the drive letter
3.3.) Cleaning
3.4.) Power supply
3.5.) Removing cards from the drive
3.6.) Linear FLASH Cards
4.) Deinstallation
5.) Software
5.1.) Utilities
5.2.) Additional products
Tested PC Cards
Known problems
Technical Data
Contact CSM
The copyright for all the software and documentation of the OmniDrive USB Professional's shipping contents belong exclusively to CSM GmbH, Filderstadt (Germany).
It is assertively not permitted, ..
- to duplicate the software for other purposes than to make backup copies, or to duplicate even parts of the documentation.
- to use the software on more than one computer at a time.
- to modify the software or even parts of the documentation.
- to pass on the software or the documentation to others
- to change or remove labels or marks from software, documentation or hardware.
Software and documentation have been carefully specified and tested. We assertively to not take over any liability for damages of any type, which may result from the usage of the product.
Hardware, software and documentation are delivered "as is", without any warranties about their function in the PC systems of the customer.
Hardware, Software and documentation are subject to change without notice.
The use of the device without knowledge of the operating information or outside the application limits quoted in the technical data is inadmissible.
Always transport or send OmniDrive in the original packaging.
'MS-DOS', 'Microsoft' and 'Windows' are registered trademarks of Microsoft Corporation.
All other trademarks mentioned in the text are properties of their respective
owners.
SAFETY INFORMATION
When installing and connecting the device the environmental conditions referred to in the "Technical Data" chapter and the information in the "Hardware Installation" chapter must be observed.
It is necessary to observe the information in the chapter on "Cleaning" when cleaning the device.
No objects may be plugged into the device (exception: PC Cards in the appropriate slot).
The user must not open the device.
Protect the device from excessive heat, radiation, dust, moisture or aggressive gases.
OmniDrive operates using harmless voltage. It can, however, be connected to outside devices that operate using hazardous voltage. It must be ensured on each occasion that all connected outside devices are safe to a sufficient degree and never transfer hazardous voltage to the OmniDrive. If one of the items of connected outside devices belongs to protection class I, the protective conductor connection on the outside device must have a connection to the device housing of low impedance. The valid safety regulations at the place of application are to be observed.
The screen and GND of the signal lines as well as the housing mass have an internal electric GND connection to the supply line. Never attach these connections to varying potential.
All cables and connections as well as the housing must be checked at regular intervals. Never use devices that show signs of obvious damage.
Please ensure that all device connections are operated according to the information in the chapter on "Technical Data". The individual components in the interior of the device can be subjected to excess heat if a connection is faulty. Do not therefore operate the device in environments containing easily inflammable materials or explosive gases.
Avoid electrostatic discharge to the PC card during data access by previously touching the metal housing for self-discharge.
The OmniDrive USB Professional enables access to PC Card (PCMCIA) mass storage cards.
At this time, the following types of cards are supported:
Other cards can not be operated with the OmniDrive USB Professional.
At this time, the drive supports USB 1.1 which allows transfer rates up to 1MB/sec.
| (*) | ATA means anything which behaves like an ATA PC Card: ATA FLASH/harddisk; CompactFlash or other medias in ATA emulating PC Card adapters. |
| (**) | A very simple, byte oriented programming algorithm is used for EEPROM
write. This algorithm should be supported by most EEPROM chips available. Refer to your PC Cards data book for details about specific algorithms. |
A PC running Windows 98/Me, Windows 2000 (SP2 recommended) or Windows XP with at least one free USB socket.
| NOTE (Win98) | Run the setup program before installing the hardware ! |
Use enclosed USB cable to connect the OmniDrive USB to free USB port.
| NOTE: | Windows will immediately install its own generic driver for
USB mass storage devices. This driver offers simple drive functionality an
can handle correctly formatted ATA media.
The installation of the CSM professional software offers a few functional extensions (e.g. support for SRAM-Cards, extended API's for PCM and other utilities..) |
To install the CSM professional software ...
| NOTE | If you have already installed an older version of the software, setup will remove this first. You must invoke the setup program once again in order to install the new version. |
| NOTE WinXP |
The Driver is not yet digitally signed by Microsoft and
Windows XP will complain about that. Ignore this message. Because of the missing signature, the driver can only be installed for
the one USB socket the drive is actually connected to. |
| NOTE |
Firmware - Update: If your OmniDrive USB Professional works with a firmware version earlier than V2.00, you should execute a firmware update. The most recent firmware is part of the package. You can check the firmware version with OmniControlCenter. This program is also used to update the firmware. |
SRAM/ATA-Cards can be formatted from within the explorer.
Special formats can be created with the formatter CSMFORM.EXE or with the formatting function of the PC Card Manager.
| NOTE Win 98/Me |
Especially small cards (<=2MB) should be formatted with CSMFORME or PCM. Formatting with means of the operating system may leave parts of the media unusable. |
| NOTE Win 98/Me |
Use the windows device manager in order to change the drive letter assignment. In the 'Disk Drives' branch you will find an entry for the OmniDrive USB. Look into the properties of this entry to change the drive letter assignment. |
| NOTE Win 2000/XP |
Use the windows disk management (MMC snap-in) to assign drive letters. See windows help for details about the disk management. |
For cleaning purposes the device must be disconnected from all live connections. Do not use abrasive agents or cleaning materials that dissolve plastic for cleaning purposes. Please ensure that liquid is not able to seep into the device.
Usually, the OmniDrive USB Professional is supplied via the USB cable. This is sufficient for most of the currently available media.
The usage of media with high power consumption, operation on hubs without own supply ("bus-powered") or programming linear FLASH cards may require the usage of an external power supply for the drive. An external power supply is available from CSM (art.No. 020386).
Remove any media from the OmniDrive USB Professional before connecting the external power supply.
| NOTE | A blinking (green) power-LED indicates a low voltage condition. You must use the external supply in this case |
In general, it is possible to remove the card from the drive at any time, provided that the drive isn't in access by anyone and the red busy LED is off.
Windows 2000/XP use cache write access even on removable disks. So you should not remove the media immediately after the red busy-LED goes off. Especially Windows 2000 delays writes very long.
To remove a card from the OmniDrive USB Professional ...
Alternatively you could stop the OmniDrive USB Professional by the help of the "remove hardare" icon on the task bar before removing the media from the drive (you must remove/plug in the USB connector afterwards).
The special version 'LF' of the OmniDrive USB Professional supports programming of linear FLASH cards.
At this time, the following FLASH chips are supported:
- AMD 28F010 (*)
- AMD 28F020 (*)
- AMD 29F010
- AMD 29F016
- AMD 29F016C
- AMD 29F040
- AMD 29F080
- Catalyst 28F010-12 (*)
- Fujitsu MBM29F016
- Fujitsu MBM29F040
- Fujitsu MBM29F080
- INTEL 28F004-S3/S5
- INTEL 28F008 (*)
- INTEL 28F008-S3/S5
- INTEL 28F010 (*)
- INTEL 28F016-S3/S5
- INTEL 28F016SA/SV
- INTEL 28F016XD/XS
- INTEL 28F020 (*)
- INTEL 28F320J5 (StrataFlash)
- INTEL 28F640J5 (StrataFlash)
- Mitsubishi 28F101 (*)
- SGS 28F101 (*)
- SGS 28F201 (*)
- SGS 28F841
- SGS 29F040
Refer to the data book of your FLASH card for information about the FLASH chip being used.
For programming linear FLASH cards, the utilities BCPY32 or PCM can be used.
| (*) | These chips require a programming voltage of 12V. |
Windows GUI with online help:
Console utilities:
The following additional products are available for the OmniDrive USB Professional:
| PC Card SDK | The PC Card Software Development Kit contains the complete documentation
of the driver API's for DOS/Win3.x (16-bit) as well as Windows 9x/Me and NT/2000/XP (32-bit).
Numerous samples (C/C++) demonstrate the usage of the API functions. For windows platforms, the SDK contains DLL's which encapsulate the low level API's of the drivers and offer a comfortable procedure oriented API for applications. The DLL's (MEL-DLL for Win16, resp. CSMDLL for Win32) can be used from non-C/C++ development systems as well. |
| ATATool | Utility to analyze and repair ATA cards. |
| PC Card Technology | Card | Remarks |
|---|---|---|
| SRAM | Mitsubishi MF32M1-LCDAT01 | |
| Linear FLASH ('LF'-version only) |
AMD C-Series (AMC001CFLKA) AMD D-Series (AMC004DFLKA) INTEL Series-II INTEL Value Series100 INTEL Value Series100 INTEL Value Series200 Mitsubishi MF84M1GKDAT00 Mitsubishi MF84M1GMCAT00 |
29F040 29F016C 28F008SA 28F008SA 28F016 S3/S5 28F320J5 (StrataFlash) 28F008S5 28F016S5 |
| ATA |
IBM MicroDrive 340 Toshiba MK5002MPL |
Hard-Disks |
| CSM SuperStore Mitsubishi MF0075M-03BT01 SanDisk SDP3B SiliconTech SLATAFL008A PRETEC AFH016 |
ATA-FLASH | |
| Andere |
SanDisk SDCFB PRETEC ACT032 |
CompactFlash |
| SMFV004 / FUJIFILM Adapter | SmartMedia | |
| SanDisk SDSDB / Panasonic Adapter | SD-Card |
Drive does not work if attached via USB hub
If a USB hub is powered only via the USB, the power supply for attached devices is limited (see 3.4.).
Attach either the hub or the OmniDrive USB to the mains by using a suitable AC adaptor.
CSMForm / PCM unable to format media >2GB
At this time, both formatters support only FAT12/16 format and thus are limited to <= 2GB. Use the formatting function from the operating system instead if you need to format a media with larger capacity.
Windows 2000 / SP3 fails to recognize cards
In Windows 2000 SP3 it may happen that the operating systems fails to recognize cards or is unable to read the format of the card.
This problem may occur with firmware versions prior to V2.20. Use OmniControl to check the firmware version of your OmniDrive USB. Use OmniControl to update the firmware of your OmniDrive USB. The most recent firmware is always included in the driver setup package. The most recent driver setup package can be found on our web site.
Windows 9x/Me: Concurrent Access from operating system and utilities causes troubles
If you use utilities that access the drive via the CSM DeviceIoControl-API while the operating system accesses the drive via file system (e.g. copy files in the explorer), the system may hang.
|
Item |
OmniDrive USB |
OmniDrive USB Professional |
||
|---|---|---|---|---|
|
PC Card Slots |
1x type II front slot |
|||
|
Interface |
USB 1.1 (12 MBit/s) |
|||
|
Data Transfer Rate |
up to 1 MByte/s |
|||
|
PC Card Types |
|
SRAM; |
||
|
Software |
- |
CSM Professional Software PC Card Manager (PCM) OmniCtrl, BCPY32, CSMFORM |
||
|
Dimensions (W x H x D) |
109 mm x 35 mm x 135 mm |
|||
|
Weight |
approx. 300 g |
|||
|
Operating Temperature |
0°C to +70°C 1) |
|||
|
Non-operating Temperature |
-20°C to +85°C 1) |
|||
|
Humidity |
max. 90% (not condensing) |
|||
|
Power Supply |
DC 5 V from PC via USB bus |
|||
|
System Requirements |
PC with Win 98/Me, Win 2000, Win XP or Linux 2) |
PC with Win 98/Me, Win 2000 or Win XP |
||
|
Conformity |
|
|||
|
1) Optional -40°C to +85°C (operating and non-operating).2) Other operating systems on request. |
||||
|
Shipping Contents: |
||||
|
OmniDrive USB
Options:
|
OmniDrive USB Professional Same as OmniDrive USB, additionally
Additional products:
contents using own applications CSM API-32, DLLs and code examples |
|||
If you have a problem which cannot be resolved by the help of this information, please send a detailed description of your problem and your system configuration to CSM.
Most recent information about CSM products and software downloads can be found on our Web-site.
| Support-Formular: | http://www.csm.de/en_supportform.htm |
| EMail: | support@csm.de |
| Web: | http://www.csm.de |
Revised: 14.10.2003